INVT CHE100 is a general-purpose frequency inverter known for its Sensorless Vector Control (SVC) V/f control

PV array voltage matching

The INVT CHE100 User Manual serves as a critical document for ensuring the longevity and efficiency of solar water pumping systems. The device is highly specialized for off-grid agricultural use. Strict adherence to the manual’s guidelines regarding , proper grounding , and motor parameter tuning is required for successful deployment. The unit offers a cost-effective, low-maintenance solution for remote water pumping applications.

Communication

: Integrated RS485 interface supporting standard Modbus protocol. Basic Configuration & Parameter Settings

Grounding:

Ensure the inverter is properly grounded to avoid electrostatic damage and reduce noise. Common Parameter Settings

Conclusion

Problem 2: The inverter trips on ERR02 (Overvoltage) when decelerating.

Manual solution:

Increase deceleration time (P0.16) or enable overvoltage stall protection (P3.08 = 1 ). For loads with high inertia, install a braking resistor (see wiring diagram in Chapter 3).

4.2. Mechanical and Electrical Installation (Chapter 2-3)